Product Details

LA-AD-018 ADSS Short Span ~288F

Description

Loose Tube / Gel-Filled / All Dielectric
Single Jacket None Armored Optical Fiber Cable

Lexington Ames LA-ADSS-018 series for standard short-span has been engineered for standing the America’s toughest weather conditions. The LA-ADSS-018 cable is ideal for the routes with 300 feet maximum span under NESC-Heavy condition or 650 feet under NESC-Light condition. Download the spec sheet to find more details on sag and tension information.

The PBT loose tube and the Medium Density Polyethylene jacket provide flexibility in handling yet solid protection of the core glasses from UV and other outside forces.

Standards and Certifications

ITU-T G.650. G.652.D. IEC 60793, 60794. IEEE 1222. RUS 7 CFR 1755. ISO 9001, 14001, OHSAS 18001. TIA-598-D. GR-20 (glass)

Construction

The cable core consists of color coded fibers, Thixotropic jelly compound, dry water swellable material, color coded PP loose tubes, PE filler (if necessary), SZ-stranded around the FRP central strength member with water blocking yarn(s).

The cable structure is completed by the application of a core wrapping tape, auxiliary strength member if necessary, which with the core, are covered by an outer MDPE jacket.

 

Optical Characteristics

Type of Fiber   G.652D
Mode Field Diameter @1310nm μm 9.2 ± 0.4
Mode Field Concentricity Error μm ≤ 1.0
Cladding Diameter μm 125 ± 1.0
Cladding Non-circularity % ≤ 1.0
Transmission wavelength nm 1310, 1550
Attenuation (Max. 144C) dB/km ≤ 0.35 @ 1310 nm
≤ 0.25 @ 1550 nm

 

Dimension

Fiber Count Tube Count Diameter (inch) Weight (lbs/kft)
~ 72 6 0.425 (10.8mm) 59 (88kg/km)
96 8 0.476 (12.1mm) 75 (112kg/km)
144 12 0.587 (14.9mm) 114 (170kg/km)
192 ~ 216 18 (6+12) 0.610 (15.5mm) 115 (171kg/km)
288 24 (9+15) 0.689 (17.5mm) 151 (225kg/km)

 

Sag and Tension (~72 count)

Weather Condition NESC Light NESC Medium NESC Heavy
Max. Rated Cable Load (MRCL) 1349lb (6000N) 1349lb (6000N) 1349lb (6000N)
Max. Span 656ft (200m) 509ft (155m) 300ft (91m)
Initial Sag 1.0% 1.0% 1.0%
Sag 3.2% 3.4% 3.7%
Loaded Tension 1002lb (454kgf) 930lb (422kgf) 884lb (401kgf)

 

Sag and Tension (96 count)

Weather Condition NESC Light NESC Medium NESC Heavy
Max. Rated Cable Load (MRCL) 1529lb (6800N) 1529lb (6800N) 1529lb (6800N)
Max. Span 607ft (185m) 509ft (155m) 300ft (91m)
Initial Sag 1.0% 1.0% 1.0%
Sag 3.0% 3.2% 3.6%
Loaded Tension 1100lb (499kgf) 1057lb (479kgf) 979lb (444kgf)

 

Sag and Tension (144 count)

Weather Condition NESC Light NESC Medium NESC Heavy
Max. Rated Cable Load (MRCL) 1933lb (8600N) 1933lb (8600N) 1933lb (8600N)
Max. Span 509ft (155m) 410ft (125m) 300ft (91.4m)
Initial Sag 1.0% 1.0% 1.0%
Sag 2.7% 2.8% 3.3%
Loaded Tension 1282lb (581kgf) 1156lb (525kgf) 1206lb (547kgf)

 

Sag and Tension (192-216 count)

Weather Condition NESC Light NESC Medium NESC Heavy
Max. Rated Cable Load (MRCL) 1933lb (8600N) 1933lb (8600N) 1933lb (8600N)
Max. Span 509ft (155m) 410ft (125m) 300ft (91.4m)
Initial Sag 1.0% 1.0% 1.0%
Sag 2.7% 2.8% 3.3%
Loaded Tension 1314lb (596kgf) 1178lb (534kgf) 1229lb (557kgf)

 

Sag and Tension (288 count)

Weather Condition NESC Light NESC Medium NESC Heavy
Max. Rated Cable Load (MRCL) 2360lb (10500N) 2360lb (10500N) 2360lb (10500N)
Max. Span 509ft (155m) 410ft (125m) 300ft (91.4m)
Initial Sag 1.0% 1.0% 1.0%
Sag 2.6% 2.6% 3.2%
Loaded Tension 1608 (730kgf) 1419lb (644kgf) 1435lb (651kgf)